Large Above Grade and Below Grade Lift Stations
HFE Process, a custom lift station supplier based in Tulsa OK, has over 30 years of experience in developing and building custom built lift stations. 

Lift stations can be small 80 gpm stations for sewage pumping to  large 5000 gpm factory built pump stations for water and wastewater treatment systems.   The larger the project pump station the more complicated design in controls and layout. 

Pump stations are specifically designed for the application based uopn engineer's specifications and the pumps pecifically built for the application.  Typically pumps are manufactured by quality suppliers such as Cornell or Fairbanks Morse pump companies. 

Calculations for extended B-10 bearing life, various types of seals, and pump orientation are available depending on the duty conditions for each pump system. 

Controls can be of a many variety design; Variable Speed Drives, Soft Start Controls, 4-20 ma input level controls, Magnetic Flow meters and SCADA communication are all custom design based upon the engineer's specifications. 

Projects have been fabricated from complete corrosion resistent FRP materials to large multi-pump steel enclosures with entrance tubes to the pump chambers.   Hoists and cranes are installed for easy maintenance.


 
Entrance Tube to "Buried Can" lift station for operator entrance to pump chamber.

Conduit connections and Limit Switch for ventilation fan located above grade level for water proof.  Ventilation fan turns "on" when lid is opened to exhaust any accumulated gas.
Sump Pumps located at bottom of the can pump drainage and spilled water back into forceain or wetwell
Pump station before housing is installed over the top and controls connected. 

Pump station is factory built and then shipped to the jobsite tested ready for operation.

Water Booster Station with 3000 gpm pumps installed in a factory built station with controls etc.
Customized controls for pump station.   Controls to be NEC compliant with UL labels as required by specifications.

Controls factory tested, assembled and shipped to the jobsite.

SCADA ready as required by specification.  FIber optic or ethernet depending on the electrical design requirements of the project for SCADA
HFE Process

A complete pump station manufacturer building quality products with performance!!!